Search results for "Facet joint"
showing 8 items of 8 documents
Maintenance of Integrity of Upper Facet Joints during Simulated Percutaneous Pedicle Screw Insertion Using 2D versus 3D Planning
2019
Background No studies have directly and quantitatively compared two-dimensional (2D) and three-dimensional (3D) planning as applied during conventional percutaneous or navigated percutaneous pedicle screw placement. Study Aims This lumbar pedicle-based stabilization simulation study aimed to investigate the risk of upper facet joint violation (FJV) during posterior percutaneous pedicle screw placement with conventional 2D planning of screw implantation (as a model for fluoroscopically guided screws) compared with 3D planning (as used with navigation techniques). Methods The placement of monosegmental lumbar pedicle screws using the data sets of 250 consecutive patients was simulated. Conve…
Radiofrequency Ablation for Chronic Lumbar Zygapophyseal Joint Pain Using a V-Shaped Active Tip Needle: An Observational Retrospective Study
2023
Giuliano Lo Bianco,1,2 Giovanni Misseri,2 Agnes R Stogicza,3 Gregoretti Cesare,2,4 Sean Li,5 Miles Day,6 David J Kennedy,7 Michael E Schatman8,9 1Department of Biomedical and Biotechnological Sciences, University of Catania, Catania, Italy; 2Anesthesiology and Pain Department, Fondazione Istituto âG. Giglioâ, Cefalù, Palermo, Italy; 3Anesthesia and Pain, Saint Magdolna Private Hospital, Budapest, Hungary; 4Department of Surgical, Oncological and Oral Science (Di.Chir.On.S.), University of Palermo, Palermo, Italy; 5National Spine and Pain Centers, Shrewsbury, NJ, USA; 6Pain Research, The Pain Center at Grace Clinic, Texas Tech University HSC, Lubbock, TX, USA; 7Department of PM&R, V…
Tissue Sparing Posterior Cervical Indirect Decompression and Fusion in Foraminal Stenosis
2016
Treatment for patients with cervical foraminal stenosis that present with cervical radiculopathy has experienced rapid progress. Cervical spine surgical options have improved through advances in imaging, instrumentation, implant innovations and novel surgical techniques. While historical treatments are largely safe, comorbidities associated with procedures such as ACDF, TDR, and posterior foraminotomy beg the question if these procedures are too much surgery for select patients that could benefit from a tissue sparing approach. This chapter will introduce a novel, less disruptive surgical technique for achieving indirect decompression and fusion utilizing an intervertebral cervical implant.…
Effect of lumbar disc replacement on the height of the disc space and the geometry of the facet joints: a cadaver study.
2010
In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p < 0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p < 0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantl…
Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion T…
2017
Background Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint. Study Aims We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation. Methods A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups acc…
Load Distribution in the Lumbar Spine During Modeled Compression Depends on Lordosis.
2021
Excessive or incorrect loading of lumbar spinal structures is commonly assumed as one of the factors to accelerate degenerative processes, which may lead to lower back pain. Accordingly, the mechanics of the spine under medical conditions, such as scoliosis or spondylolisthesis, is well-investigated. Treatments via both conventional therapy and surgical methods alike aim at restoring a “healthy” (or at least pain-free) load distribution. Yet, surprisingly little is known about the inter-subject variability of load bearings within a “healthy” lumbar spine. Hence, we utilized computer tomography data from 28 trauma-room patients, whose lumbar spines showed no visible sign of degeneration, to …
Case series of fluoroscopic findings and 3D reconstruction of human spinal MRIs of the space of Okada.
2020
Objective To better understand the unexpected spread of contrast medium observed by conventional fluoroscopic X-ray images during standard neuraxial techniques used in the treatment of pain. The support of 3D reconstruction of MRI images of structures within the lumbar spine was used to better understand the space of Okada. Methods Lumbar facet joint and epidural corticosteroid injections in five patients under fluoroscopic guidance with loss of resistance to air or saline to identify the facet joints or epidural space. Next, in a retrospective study, the authors examined the retrodural space of Okada and the neighboring tissues with 3D reconstruction of spinal MRIs of seven patients withou…
Die Sonographie der Lendenwirbelsäule und des lumbosakralen Überganges - Sonoanatomie und Möglichkeiten der sonographisch gesteuerten Facettengelenks…
2008
QUESTION Is sonography helpful in facet joint infiltration of the lumbar spine? METHOD The sonoanatomy of the lumbar spine and the of lumbosacral junction was examined and described in a skeleton and in 10 volunteers. One representative cross section and 3 longitudinal sections were defined. According to these results (no neurological symptoms) the possibilities of ultrasound guided infiltration of the facet joints was examined in 78 patients (36 female, 42 male, average age 55 y., 38-78 y.) with chronic low back pain and increase of pain by hyperextension. 5 ml Carbostesin partially in combination with steroids were applied to each joint. In all cases the tip of the syringe could be placed…